|
Contact Information
Tel: (852) 27665859 Fax :(852) 27657198 Email: besmd@polyu.edu.hk
Room FJ726, Chan Tai Ho Building Department of Building Services Engineering |
Dr. Deng Shiming 鄧仕明 Associate Professor and |
| Dr.
Deng Shi-Ming graduated from Tong-Ji
University,
Research Interests Dr. Deng's research interests include: direct expansion (DX) air conditioning and refrigeration system simulation and control strategies development; applying air conditioning and thermal comfort in sleeping environment in tropics or subtropics; building energy use performance analysis including building energy audit and benchmarking (in particular for hotel buildings). Dr. Deng has published totally over 70 papers. Currently, Dr. Deng leads a research group of DX and residential air conditioning technology, and there are three PhD students and a few master students working in the group. Recently, with the support of a large equipment fund from the university, the Laboratory of DX Air Conditioning Technology has been set up in the department. Over the years, the total amount of research grants from various sources exceeds five millions Hong Kong Dollars. In addition, based on extensive research experiences, Dr. Deng has carried out a number of high-level consultancy projects related to building energy audits, HVAC systems performance evaluation and optimization, etc.
Selected Publications
Chen W, Deng S M
and Zhou X. "Development of Control Method and Dynamic Model for Multi-Evaporator
Air Conditioners (MEAC)", Accepted by Energy Conversion and Management.
2004
Yao Y, Jiang Y Q, Deng S M and Ma Z L. "Distributed Modeling of the Airside Heat Exchanger under Frosting in an Air Source Heat Pump Water Heater /Chiller Unit", Accepted by International Journal of Heat and Mass Transfer. 2004 Lin Z P and Deng S M. "A study on the characteristics of nighttime bedroom cooling load in tropics and sub-tropics", Buildings and Environment (in press). 2004 Deng S M and Jiang Y Q. "Retrofitting Hot Water Supply in Hong Kong Luxury Hotel", ASHRAE Journal December, pp52-55. 2003 Lin Z P and Deng S M "The outdoor air ventilation rate in high-rise residences employing room air conditioners", Buildings and Environment, Vol. 38, No. 12, pp 1389-1399. 2003 Jiang Y Q, Han H and Deng S M. "A study on residential clothes drying using waste heat rejected from a split-type room air conditioner (RAC)", Drying Technology, Vol. 21, No. 8 pp1473-1492. 2003
Deng S M, "Energy and water uses
and their performance explanatory indicators in hotels in Tan K X and Deng S M, "A Numerical Analysis of Heat and Mass Transfer inside a Reversibly Used Water Cooling Tower (RUWCT)", Buildings and Environment, Vol. 38, No. 1, pp 91-97. 2003 Deng S M, "Sizing Replacement Chiller Plants", ASHRAE Journal. June. pp 47-49. 2002 Tan K X and Deng S M, "A simulation study on a water chiller complete with a desuperheater and a reversibly used water cooling tower (RUWCT) for service hot water generation", Buildings and Environment, Vol. 37, No. 7, pp741-751. 2002 Tan K X and Deng S M, "A method for evaluating the heat and mass transfer characteristics in a reversibly used water cooling tower (RUWCT) for heat recovery", International J. of Refrigeration, Vol. 25, No.5, pp 552-561. 2002 Deng S M, "The application of feedforward control in a direct expansion (DX) air conditioning plant", Buildings and Environment, Vol. 37, No.1, pp 35-40. 2002 Tan K X and Deng S M,
"Desuperheater heat recovery hot water heating
systems in subtropics: using water cooling towers to extract heat
from ambient air as heat source". ASHRAE Transaction. Vol. 107, Part
2, pp.608-612. 2001 Deng S M, "A dynamic mathematical model of a direct expansion (DX) water-cooled air conditioning plant", Buildings and Environment, Vol. 35 No. 7, pp. 603-613. 2000 Deng S M and Ma, W B," Experimental
studies on the characteristics of an absorber using LiBr/H2O
solution as working fluid", International J. of Refrigeration, Vol. 22,
No.4, pp293-301. 1999 Deng S M and Missenden, J, "Validation and simplification for a dynamic mathematical model of an air conditioning plant using classical control theory", ASHRAE Transaction, Vol. 105, Part 1, pp140-148.1999 Deng S M and Tung, D, "Performance evaluation for a VAV air conditioning system under reduced static pressure control", BSER&T, Vol. 18, No. 2, pp77-83. 1997 Deng S M and Ma, W B, "Theoretical analysis of low temperature hot water source driven two stage absorption refrigeration systems", International Journal of Refrigeration, Vol. 19 No. 2, pp. 141-146. 1996 |