Dr. Deng Shiming 仕明

 

Associate Professor and
Associate Head of Department

 

 

Dr. Deng Shi-Ming graduated from Tong-Ji University, Shanghai, China, with a bachelor degree in HVAC Engineering in 1983. He then worked for three years in Shanghai as an HVAC consulting engineer. In 1991, he obtained his PhD in Environmental Engineering from South Bank Polytechnic, UK. He joined The Hong Kong Polytechnic University as a lecturer in 1992 and is now an Associate Professor in the Department of Building Services Engineering. He is a member of The Hong Kong Institution of Engineers (HKIE), and American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE).

 

 

 

 

Research Interests

 

Dr. Deng's research interests include: direct expansion (DX) air conditioning and refrigeration system simulation and control strategies development; applying air conditioning and thermal comfort in sleeping environment in tropics or subtropics; building energy use performance analysis including building energy audit and benchmarking (in particular for hotel buildings). Dr. Deng has published totally over 70 papers. Currently, Dr. Deng leads a research group of DX and residential air conditioning technology, and there are three PhD students and a few master students working in the group. Recently, with the support of a large equipment fund from the university, the Laboratory of DX Air Conditioning Technology has been set up in the department. Over the years, the total amount of research grants from various sources exceeds five millions Hong Kong Dollars.

 

In addition, based on extensive research experiences, Dr. Deng has carried out a number of high-level consultancy projects related to building energy audits, HVAC systems performance evaluation and optimization, etc.

 

Selected Publications

 

Chen W, Deng S M and Zhou X. "Development of Control Method and Dynamic Model for Multi-Evaporator Air Conditioners (MEAC)", Accepted by Energy Conversion and Management. 2004

 

Yao Y, Jiang Y Q, Deng S M and Ma Z L. "Distributed Modeling of the Airside Heat Exchanger under Frosting in an Air Source Heat Pump Water Heater /Chiller Unit", Accepted by International Journal of Heat and Mass Transfer. 2004

 

Lin Z P and Deng S M. "A study on the characteristics of nighttime bedroom cooling load in tropics and sub-tropics", Buildings and Environment (in press). 2004

 

Deng S M and Jiang Y Q. "Retrofitting Hot Water Supply in Hong Kong Luxury Hotel", ASHRAE Journal December, pp52-55. 2003

 

Lin Z P and Deng S M "The outdoor air ventilation rate in high-rise residences employing room air conditioners", Buildings and Environment, Vol. 38, No. 12, pp 1389-1399. 2003

 

Jiang Y Q, Yao Y, Deng S M and Ma Z L.  "Applying Grey Forecasting to Predicting the Operating Energy Performance of Air Cooled Water Chillers", International Journal of Refrigeration, 27(4), 385-392. 2004

 

Han H and Deng S M. "A study on residential clothes drying using waste heat rejected from a split-type room air conditioner (RAC)", Drying Technology, Vol. 21, No. 8 pp1473-1492. 2003

 

Deng S M, "Energy and water uses and their performance explanatory indicators in hotels in Hong Kong", Energy and Buildings Vol. 35, No. 8, pp 775-784. 2003

 

Tan K X and Deng S M, "A Numerical Analysis of Heat and Mass Transfer inside a Reversibly Used Water Cooling Tower (RUWCT)", Buildings and Environment, Vol. 38, No. 1, pp 91-97. 2003

 

Deng S M, "Sizing Replacement Chiller Plants", ASHRAE Journal. June. pp 47-49. 2002

 

Tan K X and Deng S M, "A simulation study on a water chiller complete with a desuperheater and a reversibly used water cooling tower (RUWCT) for service hot water generation", Buildings and Environment, Vol. 37, No. 7, pp741-751. 2002

 

Tan K X and Deng S M, "A method for evaluating the heat and mass transfer characteristics in a reversibly used water cooling tower (RUWCT) for heat recovery", International J. of Refrigeration, Vol. 25, No.5, pp 552-561. 2002

 

Deng S M, "The application of feedforward control in a direct expansion (DX) air conditioning plant", Buildings and Environment, Vol. 37, No.1, pp 35-40. 2002

 

Tan K X and Deng S M, "Desuperheater heat recovery hot water heating systems in subtropics: using water cooling towers to extract heat from ambient air as heat source". ASHRAE Transaction. Vol. 107, Part 2, pp.608-612. 2001

 

Deng S M, "A dynamic mathematical model of a direct expansion (DX) water-cooled air conditioning plant", Buildings and Environment, Vol. 35 No. 7, pp. 603-613. 2000

 

Deng S M and Ma, W B," Experimental studies on the characteristics of an absorber using LiBr/H2O solution as working fluid", International J. of Refrigeration, Vol. 22, No.4, pp293-301. 1999

 

Deng S M and Missenden, J, "Validation and simplification for a dynamic mathematical model of an air conditioning plant using classical control theory", ASHRAE Transaction, Vol. 105, Part 1, pp140-148.1999

 

Deng S M and Tung, D, "Performance evaluation for a VAV air conditioning system under reduced static pressure control", BSER&T, Vol. 18, No. 2, pp77-83. 1997

 

Deng S M and Ma, W B, "Theoretical analysis of low temperature hot water source driven two stage absorption refrigeration systems", International Journal of Refrigeration, Vol. 19 No. 2, pp. 141-146. 1996