| International
Journal on Engineering Performance-Based Fire Codes
|
 |
| Volume 1, Number 1,
1999 |
| CONTENTS |
A
Preliminary Discussion on Engineering
Performance-Based Fire Codes in the Hong Kong
Special Administrative Region
W.K. Chow |
p.1-10 |
Role of
Fire Field Models as a Design Tool for
Performance-Based Fire-Code Implementation
K.T. Yang |
p.11-17 |
A
Description of the Probabilistic and
Deterministic Modelling Used in FiRECAMTM
D. Yung, G.V.
Hadjisophocleous and G. Proulx |
p.18-26 |
Hand
Calculation Method for Air Supply Rates in
Vestibule Pressurization Smoke Control System
M. Kujime, T.
Matsushita and T. Tanaka |
p.27-42 |
|
 |
| Volume 1, Number 2,
1999 |
| CONTENTS |
Natural
Fires in Large Scale Compartments
B.R. Kirby,
D.E. Wainman, L.N. Tomlinson, T.R. Kay and B.N.
Peacock |
p.43-58 |
Review on
Safety Codes Relating to Karaoke Establishments
and Fire Safety Management
Gigi C.H. Lui
and W.K. Chow |
p.59-70 |
Evaluation
of Smoke Exhaustion Performance of a Vestibule
within Tall Buildings in Taiwan
K.C. Chung |
p.71-80 |
Some
Discussions on Egress Calculations - Time to Move
R. Marchant |
p.81-95 |
Letter to
the Editor
J.C. Jones |
p.96 |
Author's
Response
D. Yung |
p.97 |
|
 |
| Volume 1, Number 3,
1999 |
| CONTENTS |
Moves
Towards Performance-Based Standards in the U.K.
and in the European Committee for Standardization
(CEN)
H.P. Morgan |
p.98-103 |
Performance
Based Fire Safety Design Standards and FSE Tools
for Compliance Verification
T. Tanaka |
p.104-117 |
Five Years
of Performance-Based Fire Safety in New Zealand
A.H. Buchanan |
p.118-122 |
Cost-Effective
Fire-Safety Retrofits for Canadian Government
Office Buildings
D. Yung and
G.V. Hadjisophocleous |
p.123-128 |
Views of
Building Professionals on the Implementation
Aspects of Fire Safety Engineering Approach in
Building Design -- A Preliminary Study
S.M. Lo and
Richard K.K. Yuen |
p.129-133 |
Smoke
Control in Special Structure
D.B. Ball |
p.134-147 |
Effects of
Pressurisation and Smoke Management Systems on
Fire Growth and Smoke Movement in a Multi-Storey
Building
Y. He |
p.148-155 |
Application
of Fire Models to Fire Safety Engineering Design
M.C. Luo |
p.156-161 |
Modeling
Smoke Conditions in Large Compartments Equipped
with Mechanical Smoke Exhaust using a Two-Zone
Model
G.V.
Hadjisophocleous and Z. Fu |
p.162-167 |
Design and
Operation for Tunnel Ventilation System under
Fire Scenario
S.C. Kot,
Raymond M.H. Yau and Dennis C.W. Tang |
p.168-177 |
A Novel
Smoke Control System for Tall Atrium
Daniel P.C.
Chan, S.K. Lau and W.K. Chow |
p.178-182 |
Experimental
and Numerical Study of Smoke Conditions in an
Atrium with Mechanical Exhaust
G.V.
Hadjisophocleous and G. Lougheed |
p.183-187 |
An
Alternative Concept of Smoke Management
M.C. Hui |
p.188-195 |
Reduced
Scale Experiments for Convective Heat Transfer in
the Early Stage of Fires
T. Tanaka and
S. Yamada |
p.196-203 |
HRR, Smoke
and Toxicity of Ceiling and Wall Linings and
Finishes
M.Y.L. Chew |
p.204-212 |
Some
Fireproof Problems of High-Rise Building
Z. Hu, G. Tu
and Y. Xing |
p.213-217 |
|
 |
| Volume 2, Number 1,
2000 |
| CONTENTS |
Survey on
the Fire Safety Requirements in Karaoke
Establishments
W.K. Chow and
Gigi C.H. Lui |
p.1-13 |
Investigation
into Rise Time of Buoyant Fire Plume Fronts
T. Tanaka, T.
Fujita and J. Yamaguchi |
p.14-25 |
Towards a
Simplified Means of Predicting Times to Failure
of Hydrocarbon-Bearing Vessels Affected by Heat
J.C. Jones
and D. Preston |
p.26-30 |
Smoke
Control using the "Cabin Principle":
Pros and Cons of SHEVS and of Depressurisation
H.P. Morgan |
p.31-47 |
|
 |
| Volume 2, Number 2,
2000 |
| CONTENTS |
A
Horizontal Fire-Whirl Design Scenario for
Engineering Performance-Based Fire-Code
Applications
K. Satoh and
K.T. Yang |
p.48-57 |
Proposal
of Using a Time Constant for Specifying Atrium
Smoke Filling in Fire Codes
W.K. Chow and
J. Li |
p.58-60 |
Reliability
Study on Sprinkler System to be Installed in Old
High-Rise Buildings
N.K. Fong |
p.61-67 |
Smoke
Movement in Atrium Buildings
M.Y.L. Chew
and P.H. Liew |
p.68-76 |
|
 |
| Volume 2, Number 3, 2000 |
| CONTENTS |
On the Minimum Smoke
Extraction Rate for Basement Required in the Local Fire Codes
W.K. Chow |
p.77-80 |
Using Risk-Based Time
Method to Determine the Maximum Travel Distance for Building
Designs
L.D. Zhao |
p.81-89 |
J.C. Jones and K. Harper
J.C. Jones and K. Harper |
p.90-93 |
Evaluating the Smoke
Hazard from Fires in Large Spaces
J.A. Milke |
p.94-103 |
A Demonstration on
Working out Fire Safety Management Schemes for Existing Karaoke
Establishments in Hong Kong
G.C.H. Lui and W.K. Chow |
p.104-123 |
|
 |
| Volume 2, Number 4, 2000 |
| CONTENTS |
On the Sprinkler Tank
Size and Fast Response Sprinkler Heads
W.K. Chow |
p.124-126 |
Development of Performace-Based
Codes, Performance Criteria and Fire Safety Engineering Methods
G.V.
Hadjisophocleous and N. Benichou |
p.127-142 |
A
Pre-Evacuation Behavioural Study for the People in High-Rise Residential
Buildings under Fire Situations
S.M. Lo, K.C. Lam, K.K. Yuen and Z. Fang |
p.143-152 |
A
Brief Review on Fire Regulations for Old High-Rise Commercial Buildings
in Hong Kong
L.T. Wong, W.K. Chow and Eric C.Y. Kwan |
p.153 |
|
 |
| Volume 3, Number 1, 2001 |
| CONTENTS |
An
Investigation of the Ability of a Thin Plate Heat
Flux
Device to Determine the Incident Heat Fluxes
During
Enclosure Fires
P.F. Lennon
and G.W.H. Silcock |
p.1-15 |
On
Evaluating Building Fire Safety for Business
Occupancies
W.K. Chow and
Gigi C.H. Lui |
p.16-24 |
Review on
Fire Regulations for New High-Rise
Commercial
Buildings in Hong Kong and a Brief
Comparison
with those in Overseas
W.Y. Hung and
W.K. Chow |
p.25-51 |
Review on
Fire Safety management and Application
to Hong
Kong
W.K. Chow |
p.52-58 |
|
 |
| Volume 3, Number 2,
2001 |
| CONTENTS |
Fire
Safety Requirements in Karaokes: comments
on the New
Karaoke Establishments Bill
W.K. Chow |
p.59-66 |
Reveiw on
Four Standard Tests on Flame Spreading
C.W. Leung
and W.K. Chow |
p.67-86 |
On the
Properties of a Water Curtain Discharged
from a
Drencher System
N.K. fong and
W.T. Chan |
p.87-91 |
Discussion
on Applying the American Fire Safety Evaluation
System for Business Occupancies in Hong Kong
W.K. Chow |
p.92-97 |
|
 |
| Volume 3, Number 3, 2001 |
| CONTENTS |
Preliminary Studies on Smoke Spreading Prevention and Thermal
Radiation Blockage by a Water Curtain
N.K. Fong, W.K. Chow and W.T. Chan |
p.98-103 |
Support on Carrying Out Full-Scale Burning Tests for Karaokes
W.K. Chow |
p.104-112 |
Experimental Studies on Smoke Filling in Atrium Fires
F. Liu and X.Z. Fu |
p.113-117 |
Scale Modelling Studies of Smoke Filling
L.T. Wong |
p.118-127 |
Instant Responses - On the Attack at World Trade Centre
W.K. Chow |
p.128-129 |
Commentary on Performance Criteria for Fire Safety in Enclosures
J.C. Jones |
p.130-131 |
Responses to Comments on Performance Criteria for Fire Safety in
Enclosures
G.V. Hadjisophocleous and N. Benichou |
p.132 |
Book Review
W.K. Chow |
p.133 |
|
 |
| Volume 3, Number 4, 2001 |
| CONTENTS |
Termperature Distribution Schedule of a Body at a Complex
Thermal Effect for a Fire Hazard Analysis
Y.V. Nikitin |
p.134-140 |
A Few Issues on Developing Performance Based Fire Safety Codes
L. Zhao |
p.141-150 |
A Network Model of Simulating Smoke Movement in Buildings
F. Liu, X.Z. Fu and W.K. Chow |
p.151-157 |
On the Equations for Flashover Fire in Small Compartments
R. Huo, X.H. Jin, C.L. Shi and W.K. Chow |
p.158-165 |
|
 |
| Volume 4, Number 1, 2002 |
| CONTENTS |
Preliminary Views on Implementing Engineering Performance-Based
Fire Codes in Hong Kong: What Should be Done?
W.K. Chow |
p.1-9 |
Stages in the Coalification Sequence Reflected in Oxidation
Reactivities
J.C. Jones and J. Godefroy |
p.10-12 |
Mathematical Analysis and Possible Application of the Two-Layer
Zone Model FIRM
L. Meng and W.K. Chow |
p.13-22 |
Preliminary Studies on Smoke Filtering for a Fire Engineering
Laboratory
N.K. Fong, Gigi C.H. Lui and C.W. Yue |
p.23-29 |
|